In April 2025, utilizing the first comprehensive 10 MPa hydrogen transmission pipeline testing platform established by a regional central research institute, adaptability evaluation tests were conducted on TCP 210/TCP 310 (1500 psi) for hydrogen transmission under actual operating conditions. Using equipment and tools such as online hydrogen permeation testers and hydrogen-sensitive tape, the hydrogen permeability of the pipe materials and joints was monitored in real time. The tests validated the overall feasibility, stability, and safety of the flexible composite pipeline technology for hydrogen transportation, and preliminary test results have been obtained.
| Product: | TCP 210/TCP 310 |
| Specifications And Quantity: | 2inch/3inch,1500psi,50 meters each |
| Application Scenarios: | 31-well hot water injection and liquid hydrocarbons pipeline |
| Conveyed Medium: | Hydrogen |
| Implementation Date: | April 2025 |